300/500 V Halogen Free Flexible Multi-Core Cables (HF TTR)

052XZ1-F (TSE)

300/500 V halogen free flexible multi-core cables (052XZ1-F) are designed for
electrical installations where flexibility, enhanced fire safety, and low smoke
emission are required. These cables are manufactured with fine-stranded copper
conductors and halogen free insulation materials to minimize toxic gas release
during fire.

052XZ1-F cables are suitable for indoor installations in residential, commercial,
and public buildings, especially in areas where human safety and environmental
protection are a priority.

Applications

  • Flexible electrical installations
  • Residential and commercial buildings
  • Public buildings such as hospitals and schools
  • Control panels and distribution boards
  • Areas requiring low smoke and halogen free cables

052XZ1-F cables are widely used in applications requiring flexibility combined
with high fire safety standards.

Cable Construction

  • Conductor: Fine-stranded flexible copper conductor
  • Insulation: Halogen free compound
  • Core Identification: Color coded
  • Outer Sheath: Halogen free compound

The halogen free insulation and sheath of 052XZ1-F cables ensure low smoke density
and minimal toxic gas emission during fire, while the flexible conductor structure
allows easy installation in confined spaces.

ParameterValue
Rated Voltage300/500 V
Conductor MaterialCopper (Cu)
Conductor TypeFine-stranded (Flexible)
Insulation MaterialHalogen Free Compound
Outer SheathHalogen Free Compound
Core IdentificationColor coded
Operating TemperatureMax. +70 °C
Short Circuit TemperatureMax. +160 °C
Installation TypeFixed installation
Flame RetardantIEC 60332-1
Smoke DensityLow smoke
Halogen ContentHalogen free
ParameterDescription
Conductor Resistance at 20°CAccording to IEC 60228 (Class 5)
Insulation Resistance≥ 20 MΩ·km
Test Voltage2000 V
Current Carrying CapacityAccording to installation method
StandardDescription
TSE052XZ1-F
IEC 60227Insulated Cables
IEC 60332-1Flame Retardant
CECompliant
RoHSCompliant
StandardDescription
TSE052XZ1-F
IEC 60227Insulated Cables
IEC 60332-1Flame Retardant
CECompliant
RoHSCompliant
Nominal Cross Section (mm²)Overall Diameter mm (approx.)Net Weight kg/km (approx.)Conductor DC Resistance at 20°C (max. ohm/km)Current Carrying Capacity in Air (A)
2×0,756,15526,06
2×16,46319,510
2×1,58,310313,316
2×2,59,11357,9825
2×410,31824,9532
3×0,756,56326,06
3×16,87419,510
3×1,58,411313,316
3×2,59,71567,9825
3×411,12244,9532
4×0,757,38126,06
4×17,79719,510
4×1,59,314113,316
4×2,510,61937,9825
4×412,22804,9532
5×0,757,99926,06
5×18,011719,510
5×1,59,615413,316
5×2,510,62097,9825
5×413,23324,9532

Technical values are indicative and may vary depending on conductor size and
installation conditions. For detailed technical data and project-based solutions,