0.6/1 kV Halogen Free XLPE Insulated Armoured Power Cables(N2XFGBH)

YXZ3Z1 (N2XFGBH) – Cu / XLPE / SWA / LSF

0.6/1 kV halogen free XLPE insulated steel wire armoured power cables
(YXZ3Z1 / N2XFGBH) are designed for power transmission and distribution in fixed
installations where enhanced mechanical protection, fire safety, and low smoke
emission are required.

These cables combine XLPE insulation with steel wire armouring and halogen free
sheathing materials, providing high mechanical strength, reliable electrical
performance, and minimal toxic gas emission in case of fire. They are ideal for
critical infrastructure and industrial applications.

Applications

  • Power transmission and distribution networks
  • Underground installations and direct burial
  • Industrial plants and heavy-duty installations
  • Infrastructure and utility projects
  • Public buildings requiring enhanced fire safety
  • Outdoor installations exposed to mechanical stress

Thanks to their steel wire armouring and halogen free construction, YXZ3Z1
(N2XFGBH) cables are suitable for installations where both mechanical protection
and fire safety are critical.

Cable Construction

  • Conductor: Solid or stranded copper conductor
  • Insulation: XLPE (Cross-Linked Polyethylene)
  • Inner Sheath: Halogen free compound
  • Armouring: Steel wire armour (SWA)
  • Outer Sheath: Halogen free compound (LSF)

YXZ3Z1 (N2XFGBH) cables are constructed with XLPE insulated copper conductors,
protected by steel wire armouring and halogen free inner and outer sheaths. This
design provides excellent mechanical protection, improved thermal performance,
and low smoke and toxic gas emission during fire.

ParameterValue
Rated Voltage0.6/1 kV
Conductor MaterialCopper (Cu)
Conductor TypeSolid or Stranded
Insulation MaterialXLPE
Inner SheathHalogen Free Compound
ArmouringSteel Wire Armour (SWA)
Outer SheathHalogen Free Compound (LSF)
Operating TemperatureMax. +90 °C
Short Circuit TemperatureMax. +250 °C
Installation TypeFixed installation
Suitable for Outdoor UseYes
Suitable for Direct BurialYes
Mechanical ProtectionHigh
Smoke DensityLow smoke
Halogen ContentHalogen free
Flame RetardantIEC 60332-1
ParameterDescription
Conductor Resistance at 20°CAccording to IEC 60228
Insulation Resistance≥ 20 MΩ·km
Test Voltage3.5 kV
Current Carrying CapacityAccording to IEC 60502-1
StandardDescription
VDEN2XFGBH
IEC 60502-1Low Voltage Power Cables
IEC 60332-1Flame Retardant
CECompliant
RoHSCompliant
Application Area
Underground installations
Industrial facilities
Infrastructure projects
Public buildings
Areas requiring high mechanical protection and fire safety
Nominal Cross Section (mm²)Overall Diameter mm (approx.)Net Weight kg/km (approx.)Conductor DC Resistance at 20°C (max. ohm/km)Current Carrying Capacity in Air (A)Current Carrying Capacity in Ground (A)
2 Cores
2×1.511.522512.12432
2×2.512.52757.413243
2×413.53404.614256
2×614.54153.085371
2×1016.55701.837496
2×1618.57801.1598125
3 Cores
3×1.512.025012.12432
3×2.513.03107.413243
3×414.23904.614256
3×615.34853.085371
3×1017.56751.837496
3×1619.59401.1598125
3×2523.014200.727128162
3×3525.518100.524157197
3×5029.024500.387190234
3.5 Cores (Reduced Neutral)
3×16+1020.510801.15 / 1.8398125
3×25+1624.515800.727 / 1.15128162
3×35+1626.519700.524 / 1.15157197
3×50+2530.526900.387 / 0.727190234
3×70+3535.036800.268 / 0.524242291
3×95+5040.049600.193 / 0.387293351
3×120+7044.562800.153 / 0.268339403
3×150+7048.575900.124 / 0.268389458
3×185+9554.596300.0991 / 0.193444521
3×240+12063.5125800.0754 / 0.153522611
4 Cores
4×1.513.029012.12432
4×2.514.23657.413243
4×415.54654.614256
4×616.85853.085371
4×1019.28251.837496
4×1621.511501.1598125
4×2525.517600.727128162
4×3528.522800.524157197
4×5033.031500.387190234
4×7038.043800.268242291
4×9543.559800.193293351
4×12048.575400.153339403
4×15054.594200.124389458
4×18561.0118400.0991444521
4×24069.5154500.0754522611
5 Cores
5×1.514.133512.12432
5×2.515.54307.413243
5×417.05554.614252
5×618.57103.085364
5×1021.210251.837386
5×1624.014501.1596111
5×2528.522200.727130143

Technical values are indicative and may vary depending on conductor size,
installation conditions, and applicable standards. For detailed technical data
and project-specific requirements, please contact Envoltra Cable.

Contact & Inquiry

For halogen free armoured cable solutions, technical details, and project-based
pricing, please contact Envoltra Cable sales team.