H07Z1-U, H07Z1-R (TSE)

450/750 V halogen free and flame retardant single core cables are designed for
electrical installations where enhanced fire safety and low smoke emission are
required. These cables are manufactured with copper conductors and halogen-free
insulation materials that minimize toxic gas release in case of fire.
Thanks to their flame retardant properties and environmentally friendly structure,
these cables are especially suitable for installations in public buildings,
commercial facilities, and areas with high human occupancy.
Applications
- Electrical installations in public buildings
- Commercial and residential buildings
- Hospitals, schools, and shopping centers
- Industrial control panels and switchboards
- Areas requiring low smoke and toxic gas emission
Halogen free single core cables are widely used in applications where fire safety,
low smoke density, and reduced toxic gas emission are critical for human safety.
Cable Construction
- Conductor: Solid copper conductor
- Insulation: Halogen free, flame retardant compound
- Core Identification: Color coded
Halogen free single core cables are manufactured using special insulation compounds
that do not emit corrosive or toxic gases during combustion. This construction
significantly improves safety in fire situations while maintaining reliable
electrical performance for fixed installations.
| Parameter | Value |
|---|---|
| Rated Voltage | 450/750 V |
| Conductor Material | Copper (Cu) |
| Conductor Type | Solid |
| Insulation Material | Halogen Free, Flame Retardant Compound |
| Core Identification | Color coded |
| Operating Temperature | Max. +70 °C |
| Short Circuit Temperature | Max. +160 °C |
| Installation Type | Fixed installation |
| Flame Retardant | IEC 60332-1 |
| Smoke Density | Low smoke |
| Halogen Content | Halogen free |
| Toxic Gas Emission | Low |
| Nominal Cross Section (mm2) | Overall Diameter mm (approx.) | Net Weight kg/km (approx.) | Conductor DC Resistance at 20°C (max. ohm/km) | Current Carrying Capacity in Conduit (A) | Current Carrying Capacity in Air (A) |
| 1,5 | 2,7 | 21 | 12,1 | 23 | – |
| 2,5 | 3,3 | 34 | 7,41 | 31 | – |
| 4 | 3,7 | 50 | 4,61 | 42 | – |
| 6 | 4,2 | 71 | 3,08 | 54 | – |
| 10 | 6,0 | 116 | 1,83 | 75 | – |
| 16 | 7,0 | 161 | 1,15 | 100 | – |
| 25 | 8,8 | 258 | 0,727 | 133 | 161 |
| 35 | 9,5 | 346 | 0,524 | 164 | 200 |
| 50 | 11,0 | 468 | 0,387 | 198 | 242 |
| 70 | 12,5 | 660 | 0,268 | 253 | 310 |
| 95 | 15,0 | 910 | 0,193 | 306 | 377 |
| 120 | 16,5 | 1140 | 0,153 | 354 | 437 |
| 150 | 18,0 | 1405 | 0,124 | 393 | 504 |
| 185 | 20,0 | 1745 | 0,0991 | 449 | 575 |
| 240 | 23,0 | 2295 | 0,0754 | 528 | 679 |
| 300 | 26,0 | 2900 | 0,0601 | 603 | 783 |
| 400 | 29,0 | 3700 | 0,0470 | 683 | 940 |
| Standard | Description |
|---|---|
| IEC 60227 | PVC / Halogen Free Insulated Cables |
| IEC 60332-1 | Flame Retardant |
| CE | Compliant |
| RoHS | Compliant |
| Application Area |
|---|
| Public buildings |
| Hospitals and schools |
| Commercial facilities |
| Industrial control panels |
| Areas with high fire safety requirements |
Technical values are indicative and may vary depending on conductor size,
installation conditions, and applicable standards. For detailed technical data
and project-specific requirements, please contact Envoltra Cable.