PVC Insulated Flexible Multi-Core Cables(TTR)

H05VV-F (TSE), TTR

Applications

  • Portable electrical equipment
  • Extension cords and power supply leads
  • Household appliances
  • Office and commercial equipment
  • Light industrial machinery
  • Temporary electrical installations

These cables are suitable for applications where flexibility, durability, and safe
electrical performance are required under normal mechanical stress conditions.

Construction & Technical Overview

  • Conductor: Flexible stranded copper
  • Insulation: PVC (Polyvinyl Chloride)
  • Number of Cores: Multi-core
  • Cable Type: Flexible, non-armoured
  • Rated Voltage: 300/500 V –
  • Maximum Operating Temperature: +70°C
  • Installation: Portable and flexible applications

H05VV-F (TTR) cables are designed with multiple flexible copper cores insulated with
PVC, providing excellent bending performance and resistance to normal mechanical
stresses during operation.

Technical Data

PropertyValue
Rated Voltage300/500 V
Conductor MaterialFlexible Copper
Insulation MaterialPVC
Sheath MaterialPVC
Number of CoresMulti-core
Maximum Operating Temperature+70°C
Minimum Installation Temperature−5°C
Cable TypeFlexible, non-armoured

Technical values are indicative and may vary depending on cable construction,
installation conditions, and applicable standards.

Standards & Certifications

The H05VV-F (TTR) flexible PVC insulated cables are manufactured in compliance with relevant national and international standards to ensure safety, reliability, and consistent performance.

  • TSE (Turkish Standards Institution)
  • IEC 60227
  • VDE (upon request)
  • CE compliant
  • RoHS compliant

Compliance with these standards ensures long service life, operational safety, and suitability for demanding installation environments.

Installation Notes

H05VV-F flexible cables are designed for indoor applications where mechanical stress is moderate. Proper installation ensures optimal performance and long-term reliability.

  • Suitable for indoor installations only
  • Not suitable for direct burial or outdoor use without additional protection
  • Should not be exposed to excessive mechanical stress
  • Installation must comply with local electrical regulations
  • Minimum bending radius should be respected during installation

Technical Data – H05VV-F (TTR) | 300/500 V

Rated Cross-section (mm²)Overall Diameter (Approx. mm)Net Weight (Approx. kg/km)Conductor Resistance at 20°C (Ω/km)Current Carrying Capacity (A)Delivery Length (m)
2 × 0.755.95126.06100
2 × 16.35919.510100
2 × 1.57.28013.316100
2 × 2.58.91247.9825100
2 × 410.11704.9532100
Rated Cross-section (mm²)Overall Diameter (Approx. mm)Net Weight (Approx. kg/km)Conductor Resistance at 20°C (Ω/km)Current Carrying Capacity (A)Delivery Length (m)
3G 0.756.36026.06100
3G 16.77119.510100
3G 1.57.910013.316100
3G 2.59.61557.9825100
3G 410.92154.9532100,
Rated Cross-section (mm²)Overall Diameter (Approx. mm)Net Weight (Approx. kg/km)Conductor Resistance at 20°C (Ω/km)Current Carrying Capacity (A)Delivery Length (m)
4 × 0.756.87326.06100
4 × 17.58919.510100
4 × 1.58.812613.316100
4 × 2.510.51897.9820100
4 × 411.92644.9532100
5G 0.757.79226.010.5100
5G 18.210818.512100
5G 1.59.815813.313.5100
5G 2.511.72407.9819.5100
5G 413.53364.9532100

All values are approximate and may vary depending on production tolerances.
For detailed technical data and project-specific requirements, please contact Envoltra Cable.